Combined Heat & Power Case Study — Combined Heat and Power Plant

PROJECT :CHP PLANT

Application Details: Design, supply and installation of large acoustic enclosures and ventilation systems for 2 no. 2MW engines

SUPPLY SCOPE:

Site-assembled acoustic enclosures with demountable front wall sections for major maintenance activities. Enclosures installed with 3 no. 500kg lifting beams, tested and certified on site. Ventilation system installed to each enclosure, comprising of 3 no. axial flow fans, motorised dampers, inlet filters and louvres along with appropriate attenuation and ductwork systems

PRODUCT SELECTION AND PERFORMANCE:

Enclosure internal walls designed to reduce noise levels to <75dBA at 1m to reduce noise experienced by plant operators. External portions of enclosure and ventilation attenuators designed to achieve 39dBA at 30m from installation.

Click on any image to view larger
1 /